Contact Us

Whatsapp

Woven Wire Mesh Sieves ø 200 mm / 203 mm

Woven Wire Mesh Sieves ø 200 mm / 203 mm

Specification
In the realm of material analysis & quality control, the precise characterization of particle sizes is critical. Our sieve’s specifications are designed to meet stringent Industry standards, ensuring accurate & reliable separation of particles across a range of sizes. Each sieve is designed in a Monoblock frame & made of a High-grade silicon seal for leakage-free sieving,

Our customers get an effective sieving area of more than 185mm which is uniformly tensioned wire mesh with precision welding to deliver Efficient & consistent performance, Strict compliance with the applicable National & International standards is the policy of Masse Präzise. Each sieve is designed & manufactured in strict compliance with ISO & ASTM standards, & adhesives used for filling to prevent particles from passing out from corners are also in compliance with US FDA 175.105 & 175.300FDA.

Featuring mesh sizes that cater to various analytical & processing needs. Here are the technical details of our sieve specifications, including mesh dimensions, aperture sizes, & construction materials, providing a comprehensive overview to support your material testing & processing requirements.

Technical Specifications:

Test Sieve Sizes & Specifications
Sieve Diameter/Frame size: 200/203 mm
Sieve Height/Frame height: 50 mm
Frame Alloy: Stainless Steel SS-316 L
Mesh Alloy: Stainless Steel SS-316 L
Finish Type: Mirror Finish
Sr no. Particle Size / Aparture Size ASTM Equivalent Size Model No. Technical specification
1 38µm 400 SFR8-2-M38-MF ±Y Variation for Average Opening: 2.9 µm
+X Maximum Variation for Opening: 20 µm
Number of mesh per square inch: 373
Wire Diameter: 30 µm ± 15%
2 45µm 325 SFR8-2-M45-MF ±Y Variation for Average Opening: 3.1 µm
±X Maximum Variation for Opening: 22 µm
Number of mesh per square inch: 330
Wire Diameter: 32 µm ± 15%
3 63µm 230 SFR8-2-M63-MF ±Y Variation for Average Opening: 3.7 µm
+X Maximum Variation for Opening: 26 µm
Number of mesh per square inch: 235
Wire Diameter: 45 µm ± 15%
4 75µm 200 SFR8-2-M75-MF ±Y Variation for Average Opening: 4.1 µm
±X Maximum Variation for Opening: 29 µm
Number of mesh per square inch: 203
Wire Diameter: 50 µm ± 15%
5 90µm 170 SFR8-2-M90-MF ±Y Variation for Average Opening: 4.6 µm
+X Maximum Variation for Opening: 32 µm
Number of mesh per square inch: 166
Wire Diameter: 63 µm ± 15%
6 106µm 140 SFR8-2-M106-MF ±Y Variation for Average Opening: 5.2 µm
±X Maximum Variation for Opening: 35 µm
Number of mesh per square inch: 143
Wire Diameter: 71 µm ± 15%
7 125µm 120 SFR8-2-M125-MF ±Y Variation for Average Opening: 5.8 µm
+X Maximum Variation for Opening: 38 µm
Number of mesh per square inch: 118
Wire Diameter: 90 µm ± 15%
8 150µm 100 SFR8-2-M150-MF ±Y Variation for Average Opening: 6.6 µm
±X Maximum Variation for Opening: 43 µm
Number of mesh per square inch: 101
Wire Diameter: 100 µm ± 15%
9 180µm 80 SFR8-2-M180-MF ±Y Variation for Average Opening: 7.6 µm
+X Maximum Variation for Opening: 47 µm
Number of mesh per square inch: 83
Wire Diameter: 125 µm ± 15%
10 212µm 70 SFR8-2-M212-MF ±Y Variation for Average Opening: 8.7 µm
±X Maximum Variation for Opening: 52 µm
Number of mesh per square inch: 72
Wire Diameter: 140 µm ± 15%
11 250µm 60 SFR8-2-M212-MF ±Y Variation for Average Opening: 8.7 µm
+X Maximum Variation for Opening: 52 µm
Number of mesh per square inch: 72
Wire Diameter: 140 µm ± 15%
12 355µm 45 SFR8-2-M355-MF ±Y Variation for Average Opening: 13.3 µm
±X Maximum Variation for Opening: 72 µm
Number of mesh per square inch: 44
Wire Diameter: 224 µm ± 15%
13 425µm 40 SFR8-2-M425-MF ±Y Variation for Average Opening: 15.5 µm
+X Maximum Variation for Opening: 81 µm
Number of mesh per square inch: 36
Wire Diameter: 280 µm ± 15%
14 500µm 35 SFR8-2-M500-MFF ±Y Variation for Average Opening: 18.0 µm
±X Maximum Variation for Opening: 89 µm
Number of mesh per square inch: 31
Wire Diameter: 315 µm ± 15%
15 600µm 30 SFR8-2-M600-MF ±Y Variation for Average Opening: 21.2 µm
+X Maximum Variation for Opening: 101 µm
Number of mesh per square inch: 25
Wire Diameter: 400 µm ± 15%
16 710µm 25 SFR8-2-M710-MF ±Y Variation for Average Opening: 24.7 µm
±X Maximum Variation for Opening: 112 µm
Number of mesh per square inch: 22
Wire Diameter: 450 µm ± 15%
17 850µm 20 SFR8-2-M850-MF ±Y Variation for Average Opening: 29.1 µm
+X Maximum Variation for Opening: 127 µm
Number of mesh per square inch: 19
Wire Diameter: 500 µm ± 15%
18 1mm 18 SFR8-2-M1.0-MF ±Y Variation for Average Opening: 0.034 mm
±X Maximum Variation for Opening: 0.14 mm
Number of mesh per square inch: 16
Wire Diameter: 0.56 mm ± 15%
19 1.18 16 SFR8-2-M1.18-MF ±Y Variation for Average Opening: 0.04 mm
+X Maximum Variation for Opening: 0.16 mm
Number of mesh per square inch: 14
Wire Diameter: 0.63 mm ± 15%
20 1.7mm 12 SFR8-2-M1.7-MF ±Y Variation for Average Opening: 0.056 mm
±X Maximum Variation for Opening: 0.2 mm
Number of mesh per square inch: 10
Wire Diameter: 0.8 mm ± 15%
21 2mm 10 SFR8-2-M2.0-MF ±Y Variation for Average Opening: 0.065 mm
+X Maximum Variation for Opening: 0.23 mm
Number of mesh per square inch: 9
Wire Diameter: 0.9 mm ± 15%
22 2.36mm 8 SFR8-2-M2.36-MF ±Y Variation for Average Opening: 0.076mm
±X Maximum Variation for Opening: 0.25 mm
Number of mesh per square inch: 8
Wire Diameter: 1.0 mm ± 15%
Note: Sieve sizes 4mm, 3.35mm, 2.80mm & 32 ?m made available as per requirement.

Standard calibration weights are highly accurate accuracy ranging from few microgram to few milligrams, typically within a defined tolerance, often specified by national or international standards (e.g., OIML, ASTM). They are calibrated and certified to ensure precision for various calibration applications.

A standard calibration weight is a precisely manufactured weight used to calibrate weighing balances or scales. It ensures accurate measurement by providing a reference point for calibration.

Standard calibration weights are typically made from high-quality materials like non-magnetic stainless steel, brass, or special alloys. These materials are designed to resist wear, corrosion, and contamination, ensuring long-term accuracy and durability.

Standard calibration weights are classified based on their accuracy and application, such as E1, E2, F1, F2 and M1.

Precision weights are used in laboratories to calibrate balances, ensuring that measurements are accurate and reliable. They are crucial for experiments and quality control.

Handle precision weights with care, using tweezers or gloves to avoid contamination or damage. Never touch them directly, as oils or dust can affect their accuracy. For More Visit Weight Accessories